Current Electricity – BHMS Physics Study Notes
(Homoeopathy – Basic Health Sciences, 2026)
1. Simple Explanation
Electricity is the flow of electric charge (usually electrons) through a conductor (wire).
- Electric Current (I) is the rate at which the charge flows.
[ I = \frac{Q}{t}\quad (\text{Amperes, A}) ] where (Q) is charge in coulombs (C) and (t) is time in seconds (s). - A voltage (electromotive force, EMF, (V)) is the electrical potential difference that pushes the charges.
- Resistance (R) is the property of a material that opposes the flow of charges.
Ohm’s Law links these three quantities:
[
V = I \times R
]
or
[
I = \frac{V}{R}, \qquad R = \frac{V}{I}
]
2. Key Points
| Concept | Formula | Units | Notes |
|---|---|---|---|
| Current | (I = \frac{Q}{t}) | A (ampere) | 1 A = 1 C/s |
| Voltage | (V = I \times R) | V (volt) | Voltage is energy per unit charge |
| Resistance | (R = \frac{V}{I}) | Ω (ohm) | Depends on material, length, cross‑section |
| Power | (P = V \times I = I^2 R = \frac{V^2}{R}) | W (watt) | Energy per unit time |
| Series Circuit | (R_{\text{total}} = R_1 + R_2 + \dots) | Ω | Same current flows through each element |
| Parallel Circuit | (\frac{1}{R_{\text{total}}} = \frac{1}{R_1} + \frac{1}{R_2} + \dots) | Ω | Same voltage across each element |
| Conductivity | (\sigma = \frac{1}{\rho}) | S/m | Inverse of resistivity |
| Temperature Effect | (R(T) = R_0 [1 + \alpha (T - T_0)]) | Ω | Resistivity increases with temperature for metals |
| Safety | Current above 10 mA can be dangerous | A | In medical devices, keep currents low; use isolation |
Practical Considerations for Homoeopaths
- Electrical safety in clinics: use insulated tools, keep dry hands, avoid direct contact with live parts.
- Medical devices (e.g., electric stethoscopes, diagnostic instruments) obey the above laws; understanding them helps in troubleshooting.
3. Worked Example
Problem
A medical diagnostic device uses a copper wire of length (L = 2,\text{m}) and cross‑sectional area (A = 1.0 \times 10^{-6},\text{m}^2).
- Resistivity of copper at 20 °C: (\rho = 1.68 \times 10^{-8},\Omega\cdot\text{m}).
- The device supplies a voltage of (V = 12,\text{V}).
Questions
- What is the resistance of the wire?
- What current flows?
- What is the power dissipated?
Solution
1. Resistance
[
R = \rho \frac{L}{A}
= 1.68 \times 10^{-8},\Omega!\cdot!\text{m} \times \frac{2,\text{m}}{1.0 \times 10^{-6},\text{m}^2}
= 0.0336,\Omega
]
2. Current (Ohm’s Law)
[
I = \frac{V}{R} = \frac{12,\text{V}}{0.0336,\Omega} \approx 357,\text{A}
]
(This high current is unrealistic for a medical device; likely the wire is thicker or the voltage lower. For illustration only.)
3. Power
[
P = V \times I = 12,\text{V} \times 357,\text{A} \approx 4284,\text{W}
]
Alternatively, using (P = I^2 R):
[
P = (357,\text{A})^2 \times 0.0336,\Omega \approx 4284,\text{W}
]
Interpretation
- Resistance is tiny because copper is a good conductor and the wire is short.
- Current is limited only by the resistance; a low‑resistance wire allows more current.
- Power dissipated (heat) is significant; in real devices, heat must be managed.
4. Quick Revision Summary
| Topic | Formula | Quick Check |
|---|---|---|
| Current | (I = Q/t) | 1 A = 1 C/s |
| Ohm’s Law | (V = IR) | If R doubles, I halves for same V |
| Resistance | (R = \rho L/A) | Thicker wire → lower R |
| Power | (P = VI) | (P = I^2R) or (P = V^2/R) |
| Series | (R_{\text{tot}} = \sum R_i) | Same I flows |
| Parallel | (1/R_{\text{tot}} = \sum 1/R_i) | Same V across each |
| Safety | Keep currents < 10 mA in contact | Use insulated tools |
Mnemonic
- Ohm’s Law: Open Loop (V = IR).
- Power: Push In Resistance (P = V I).
Remember: In medical practice,