Current electricity

Electrodynamics · free study notes · Updated

Current Electricity – BHMS Physics Study Notes

(Homoeopathy – Basic Health Sciences, 2026)


1. Simple Explanation

Electricity is the flow of electric charge (usually electrons) through a conductor (wire).

  • Electric Current (I) is the rate at which the charge flows.
    [ I = \frac{Q}{t}\quad (\text{Amperes, A}) ] where (Q) is charge in coulombs (C) and (t) is time in seconds (s).
  • A voltage (electromotive force, EMF, (V)) is the electrical potential difference that pushes the charges.
  • Resistance (R) is the property of a material that opposes the flow of charges.

Ohm’s Law links these three quantities:
[ V = I \times R ] or
[ I = \frac{V}{R}, \qquad R = \frac{V}{I} ]


2. Key Points

Concept Formula Units Notes
Current (I = \frac{Q}{t}) A (ampere) 1 A = 1 C/s
Voltage (V = I \times R) V (volt) Voltage is energy per unit charge
Resistance (R = \frac{V}{I}) Ω (ohm) Depends on material, length, cross‑section
Power (P = V \times I = I^2 R = \frac{V^2}{R}) W (watt) Energy per unit time
Series Circuit (R_{\text{total}} = R_1 + R_2 + \dots) Ω Same current flows through each element
Parallel Circuit (\frac{1}{R_{\text{total}}} = \frac{1}{R_1} + \frac{1}{R_2} + \dots) Ω Same voltage across each element
Conductivity (\sigma = \frac{1}{\rho}) S/m Inverse of resistivity
Temperature Effect (R(T) = R_0 [1 + \alpha (T - T_0)]) Ω Resistivity increases with temperature for metals
Safety Current above 10 mA can be dangerous A In medical devices, keep currents low; use isolation

Practical Considerations for Homoeopaths

  • Electrical safety in clinics: use insulated tools, keep dry hands, avoid direct contact with live parts.
  • Medical devices (e.g., electric stethoscopes, diagnostic instruments) obey the above laws; understanding them helps in troubleshooting.

3. Worked Example

Problem

A medical diagnostic device uses a copper wire of length (L = 2,\text{m}) and cross‑sectional area (A = 1.0 \times 10^{-6},\text{m}^2).

  • Resistivity of copper at 20 °C: (\rho = 1.68 \times 10^{-8},\Omega\cdot\text{m}).
  • The device supplies a voltage of (V = 12,\text{V}).

Questions

  1. What is the resistance of the wire?
  2. What current flows?
  3. What is the power dissipated?

Solution

1. Resistance
[ R = \rho \frac{L}{A} = 1.68 \times 10^{-8},\Omega!\cdot!\text{m} \times \frac{2,\text{m}}{1.0 \times 10^{-6},\text{m}^2} = 0.0336,\Omega ]

2. Current (Ohm’s Law)
[ I = \frac{V}{R} = \frac{12,\text{V}}{0.0336,\Omega} \approx 357,\text{A} ]

(This high current is unrealistic for a medical device; likely the wire is thicker or the voltage lower. For illustration only.)

3. Power
[ P = V \times I = 12,\text{V} \times 357,\text{A} \approx 4284,\text{W} ]

Alternatively, using (P = I^2 R):
[ P = (357,\text{A})^2 \times 0.0336,\Omega \approx 4284,\text{W} ]

Interpretation

  • Resistance is tiny because copper is a good conductor and the wire is short.
  • Current is limited only by the resistance; a low‑resistance wire allows more current.
  • Power dissipated (heat) is significant; in real devices, heat must be managed.

4. Quick Revision Summary

Topic Formula Quick Check
Current (I = Q/t) 1 A = 1 C/s
Ohm’s Law (V = IR) If R doubles, I halves for same V
Resistance (R = \rho L/A) Thicker wire → lower R
Power (P = VI) (P = I^2R) or (P = V^2/R)
Series (R_{\text{tot}} = \sum R_i) Same I flows
Parallel (1/R_{\text{tot}} = \sum 1/R_i) Same V across each
Safety Keep currents < 10 mA in contact Use insulated tools

Mnemonic

  • Ohm’s Law: Open Loop (V = IR).
  • Power: Push In Resistance (P = V I).

Remember: In medical practice,

Your note

Page 1

Doubt hai is topic me?

Free AI teacher se poocho — 24/7, step by step.