Galvanometer – IIT‑JEE (Main + Advanced) Study Notes
Scope – Basic theory, operation, calibration, and applications in JEE Physics.
Key formulas –
[ \theta = \frac{N B I l}{\kappa} ] [ T = 2\pi\sqrt{\frac{I}{N B I l}} ] [ \frac{d\theta}{dt} = \frac{N B l}{R},I ]
1. Conceptual Overview
| Item | Explanation |
|---|---|
| Galvanometer | A sensitive instrument that measures electric current by the deflection of a magnetic needle or a coil in a magnetic field. |
| Types | 1. D'Arsonval (Moving‑coil) galvanometer – most common in JEE. 2. Moving‑magnet galvanometer – less common. 3. Electro‑static / magnetic‑tension variants. |
| Principle | Lorentz force on current‑carrying conductor in a magnetic field produces torque, which is balanced by elastic restoring torque. |
| Components | 1. Coil of (N) turns, area (A), length (l) of conductor in field. 2. Uniform magnetic field (B). 3. Pivoted needle / coil. 4. Elastic (spring) restoring torque constant (\kappa). 5. Resistance (R) of coil. |
2. Derivation of Operating Equation
-
Force on a single turn
For a conductor of length (l) carrying current (I) in a magnetic field (B) (perpendicular), Lorentz force magnitude: [ F = I, l, B ] -
Torque on one turn
Torque about pivot: [ \tau = F \cdot r = I, l, B \cdot r ] For a uniformly wound coil, (r) is the distance from pivot to the wire. For simple derivation we absorb (r) into effective length (l_{\text{eff}}).
Thus, for (N) turns: [ \tau_{\text{mag}} = N, I, l_{\text{eff}}, B ] -
Elastic restoring torque
Hooke’s law for small angles: [ \tau_{\text{el}} = -\kappa \theta ] -
Equilibrium (static)
At equilibrium, (\tau_{\text{mag}} + \tau_{\text{el}} = 0): [ N, I, l_{\text{eff}}, B = \kappa \theta ] Operating equation: [ \boxed{\theta = \frac{N B l_{\text{eff}}}{\kappa}, I} ] This linear relation is the basis for calibration.
-
Dynamic behaviour
For time‑dependent current, Newton’s second law for rotation: [ I_{\text{rot}} \frac{d^2\theta}{dt^2} + \gamma \frac{d\theta}{dt} + \kappa \theta = N B l_{\text{eff}} I(t) ] Here (I_{\text{rot}}) is the moment of inertia of the coil + needle, (\gamma) is damping coefficient (e.g., air resistance).
For a damped harmonic oscillator the period (T) is: [ T = \frac{2\pi}{\sqrt{\frac{\kappa}{I_{\text{rot}}} - \frac{\gamma^2}{4 I_{\text{rot}}^2}}} ] -
Electrical model
The coil behaves as a resistor (R). The induced EMF (e) when (\theta) changes: [ e = -N B l_{\text{eff}} \frac{d\theta}{dt} ] This EMF opposes the applied current (Lenz’s law). The circuit equation: [ V = I R + e ] For a steady current, (e=0) and (I=V/R).
3. Calibration & Sensitivity
| Parameter | Effect |
|---|---|
| (N) (turns) | Higher (N) → larger torque → greater deflection for same (I). |
| (B) | Stronger field → linear increase in sensitivity. |
| (l_{\text{eff}}) | Longer effective length → higher torque. |
| (\kappa) | Softer spring (smaller (\kappa)) → larger deflection → higher sensitivity, but also reduces linearity range. |
| (R) | Determines (I=V/R) and influences back‑EMF. |
Sensitivity (S = \frac{d\theta}{dI} = \frac{N B l_{\text{eff}}}{\kappa}).
Maximum current for linearity: when (\theta) stays within the elastic range, typically (|\theta| < 5^\circ).
4. Common JEE Problem Themes
-
Determining current from deflection.
- Use calibrated scale: (\theta = k I).
- If linearity fails, use quadratic correction.
-
Damped oscillations.
- Find period (T) or damping factor (\gamma) from given data.
-
Electromagnetic induction in galvanometer.
- When a magnetic needle moves, induced EMF is given by Faraday’s law; relate to current.
-
Energy dissipation.
- Power dissipated in coil (P = I^2 R).
- Mechanical energy stored in spring (U = \frac{1}{2}\kappa \theta^2).
-
Galvanometer as an integrator.
- With heavy damping, (\theta(t)) becomes proportional to time‑integral of current.
5. Tricky Points & Common Mistakes
| Mistake | Why it’s wrong | Correct approach |
|---|---|---|
| Assuming (\theta) is directly proportional to (\sqrt{I}). | Misreads the magnetic torque formula. | Use ( \theta = \frac{N B l_{\text{eff}}}{\kappa} I). |
| Ignoring back‑EMF in dynamic |